Re: Times and Temperatures


  • From: George L Smyth <GLSmyth@xxxxxxx>
  • Subject: Re: Times and Temperatures
  • Date: Mon, 28 Oct 1996 17:23:32 -0500

Robert Long wrote:
> 
> It was one I no longer have a copy of in which you outlines HIE
> specifics in list form.  That's why I questioned it when you
> originally posted it:  You showed D-76 1:1 as needing 10 minutes at
> 70F or 11 minutes at 68F--I forget which.  Those are the times for
> full-strength D-76 as recommended by Kodak and appearing in the old
> PhotoLab Index T&T chart that I've been using for as many years as
> I've been using my Nikor developing tanks.

There's the problem.  You're comparing the time I mentioned for D76 1+1
with another's time for D76 stock.  You really can't do that.  The way I
develop HIE may well be completely different from how Kodak does it, and
the results I look for are certainly different.  This is why I point to
my Web page when I make these suggestions.  If you go there, look at the
results, and realize that that isn't what you're trying to do, then
certainly don't follow the suggestions.  I started working with HIE by
following Kodak's instructions, but quickly realized that I was trying
to do something totally different, thus my departure from their
suggestions.

george

-- 