Mailinglist Archives:
Infrared
Panorama
Photo-3D
Tech-3D
Sell-3D
MF3D

Notice
This mailinglist archive is frozen since May 2001, i.e. it will stay online but will not be updated.
<-- Date Index --> <-- Thread Index --> [Author Index]

RE: Ilford Ilfotec HC and HIE Results


  • From: "Vrueh, G.J. de" <G.J.de.Vrueh@xxxxxxxxxxx>
  • Subject: RE: Ilford Ilfotec HC and HIE Results
  • Date: Tue, 12 Sep 2000 10:28:37 +0200

Hello Ibrahim,

Have you ever tried to add a wetting agent to the developer to minimise
adhesion of air bubbles to the film surface?

In the past i added about 1 ml of wetting agent per liter developer. I found
it made no difference in quality of development. This was to be expected
since the manufacturer staded it could be used for this application.

after a while i stopped using the wetting agend and have never found an air
bubble. I merely used it because i had little experience with developing and
wanted to take no risk.
I never thought of it until i read your mail and tought that if he has
trouble with air bubbles this might be a solution.

Befor you start buying a wetting agent.... (usually a non ionic surfractant)
i chould mension that most liquid dishwasher products (not the type you use
for machines) are 99% the same. In fact i have used it in my developer (just
added a drop to the developer)when i was out of wetting agend and did not
see any difference or had any problems. So why not add a drop or two of
dischwasher to the developer next time and see what happens? 

Greeting from the netherlands
Gerard de Vrueh




-----Oorspronkelijk bericht-----
Van: Ibrahim PAMUK (Ank,IH) [mailto:ibrahim@xxxxxxxxxxx]
Verzonden: dinsdag 12 september 2000 10:08
Aan: infrared posting
Onderwerp: Ilford Ilfotec HC and HIE Results


Hi everybody,

I have tested Ilford Ilfotec HC and HIE with majorly #29 where ASA was set
to 640 and measured thru the filter. I developed 5 min 45 sec for 20.5 deg
with 1+31 dilution. This developer seems to have similiar characteristics
with HC110. The negatives are better than D76 but seems to be little
overdeveloped (somewhat 0.5 stops). I again have whitespots. I did prewet
and used deminarilized water for dilution. The number of spots to be lesser
than D76, but they exist. I decided that I can not give the desicion that
this is due to manifacturing so I decided that this is due to air bubbles. I
will try to follow strickly air bubble procedures.

With 1+31 which coresponds to dil B to HC110, the time is somewhat short.
Would you believe if the time is doubled with x dilution so that air bubbles
be lesser? 


Regards,

İbrahim

İnfo Holding A.Ş.


Holding Sitesi (Holding Web)	http://www.info.com.tr
Sanal Mağaza (Cyber mall)		http://www.infoshop.com.tr
Kişisel Site (Personel Web)		http://zodiac.info.com.tr




*
****
*******
******************************************************
*  To remove yourself from this list, send:          *
*         UNSUBSCRIBE INFRARED                       *
*       to                                           *
*         MAJORDOMO@xxxxx                            *
*----------------------------------------------------*
*   For the IR-FAQ, IR-Gallery and heaps of links:   *
*  http://www.a1.nl/phomepag/markerink/mainpage.htm  *
******************************************************
*
****
*******
******************************************************
*  To remove yourself from this list, send:          *
*         UNSUBSCRIBE INFRARED                       *
*       to                                           *
*         MAJORDOMO@xxxxx                            *
*----------------------------------------------------*
*   For the IR-FAQ, IR-Gallery and heaps of links:   *
*  http://www.a1.nl/phomepag/markerink/mainpage.htm  *
******************************************************