Mailinglist Archives:
Infrared
Panorama
Photo-3D
Tech-3D
Sell-3D
MF3D

Notice
This mailinglist archive is frozen since May 2001, i.e. it will stay online but will not be updated.
<-- Date Index --> <-- Thread Index --> [Author Index]

[MF3D.FORUM:838] Re: E6 Processing


  • From: Mike Kersenbrock <michaelk@xxxxxxxxxxxx>
  • Subject: [MF3D.FORUM:838] Re: E6 Processing
  • Date: Sun, 25 Jun 2000 08:38:50 -0700

mail wrote:
> 
>   With the remarks about E6 on here lately, I began to wonder if the
> trouble might be temperature control. This is critical for E6. I recall
> that doing E4 required temperature stability within 1/2 degree and I
> don't think that changed much when E6 came out. I do know that RA4 kits
> for color printing require 1/2 degree accuracy-stability. So I would
> imagine E6 is about as fussy.

The first developer in the E6 chemistry I use has a +/- 0.3 deg. C 
accuracy spec along with the first-wash water (washing the first
developer).  Rest of the steps (and wash water) are +/- 4 deg C
which is pretty loose.  Last step (4th of the 3 step process) is
done at room temp (stabilizer containing formaldehyde and wetting
agents I think).

Not a problem (as far as I can tell) for the low end Jobo Processor
I use (CPE-2).

Mike K.